This is an HTML version of an attachment to the Official Information request 'Crash data - Memorial Road/State Highway 1 intersection'.




NOTES:
1.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
THE COMPLETE PROJECT DOCUMENTATION SET,
INCLUDING THE SPECIFICATIONS.
2.
ALL TRAFFIC SIGNAL EQUIPMENT AND INSTALLATION
SHALL COMPLY WITH THE NATIONAL TRAFFIC SIGNAL
SPECIFICATION.
3
1
3.
CONTROLLER AND POLE POSITIONS ARE INDICATIVE
ONLY. FINAL LOCATIONS TO BE DETERMINED ON SITE BY
4
THE ENGINEER.
2
4.
ALL DUCTING UNDER  ROAD CARRIAGEWAYS TO BE 2 BY
50mm DUCT FOR
100mm UPVC ORANGE ELECTRICAL CONDUIT. FEEDER
SOUTHBOUND ON RAMP
DUCTS MAY BE 32mm UPVC ORANGE ELECTRICAL
CCTV TO P148
SH1 RUSSLEY ROAD
CONDUIT.
5.
SIGNAL DUCTING CHAMBER LOCATIONS ARE INDICATIVE
ONLY AND SHOULD BE CONFIRMED ON SITE. CHAMBERS
NOTE : CONTROLLER LOCATION IS
TO BE LOCATED OUT OF MAIN PEDESTRIAN PATHS AND
APPROXIMATE ONLY. EXACT
AWAY FROM UNDERGROUND SERVICES.
LOCATION TO BE DETERMINED
ON SITE WITH THE DESIGNER.
6.
ALL LANTERNS TO USE LED LAMPS
7.
LOOPS 1 AND 14 ARE CYCLE LOOPS
8.
POLES 5 AND 22 ARE STUB POLES HOUSING CYCLE PUSH
SH1 RUSSLEY ROAD
BUTTONS. POLES 4,12,21 AND 25 ARE STANDARD POLES
THAT ALSO HOUSE CYCLE PUSH BUTTONS.
9.
CYCLE PUSHBUTTONS  BE POSITIONED SO THAT THEY
ARE ACCESSIBLE TO CYCLISTS.
10. REFER TO DRAWINGS C-11-003 & 004 FOR PHASING,
DUCTING AND CABLE REQUIREMENTS.
1
11. CONTRACTOR TO CONFIRM CABLE RUNS AND CABLE
CAPACITY REQUIREMENTS.
PB 3(30)
PB 3(30)
2
31
LEGEND:
PB 6(27)
CONTROLLER
G
SIGNAL DUCT ACCESS CHAMBER
KERBSIDE JUNCTION BOX (K.J.B.)
POST AND POST NUMBER
8
POST WITH OVERHEAD STREETLIGHT (JUSP)
POST WITH OVERHEAD MAST ARM
PB 6(27)
200mm ASPECTS - OPEN VISOR
300mm ASPECTS - OPEN VISOR
Pole Schedule
ASPECTS WITH CLOSED VISOR
pole
type
equipment
30
3 ASPECT DISPLAY
1
1
2
JUSP
STREET LIGHT + CCTV
20
3 ASPECT DISPLAY WITH SINGLE GREEN
3
5
5m MAST ARM, NO LIGHTING
28
ARROW DISPLAY
29
4
JUSP
1m OUTREACH STREET LIGHT
3 ASPECT DISPLAY WITH THREE ARROW
5
1
DISPLAY
PB 5(28)
6
1
3 ASPECT DISPLAY WITH
7
11
SUPPLEMENTARY ARROW DISPLAY
8
1
PB 5(28)
9
1
3 ASPECT DISPLAY WITH SUPPLEMENTARY
TWO ARROW DISPLAY (R, Y AND G INDICATE
10
1
COLOUR OF ARROW DISPLAY)
11
1
24
MEMORIAL AVENUE
12
1
CB 5(28)
25
21
3 ASPECT DISPLAY WITH SUPPLEMENTARY
THREE ARROW DISPLAY
13
1
22
PB 2(31)
14
JUSP
1m OUTREACH STREET LIGHT
26
PB 6(27)
PEDESTRIAN ASPECTS WITH PED PB AND
CB 5(28)
INPUT NUMBER
15
1
PB 2(31)
PB 2(31)
G
PB 2(31)
16
1
23
PEDESTRIAN CALL BOX 
17
JUSP
1m OUTREACH STREET LIGHT + CCTV
27
CB 5(28)
18
5
5m MAST ARM, NO LIGHTING
P20
PEDESTRIAN CALL PAD AND INPUT NUMBER
19
1
32mm DUCTING
20
1
50mm DUCT FOR CCTV
100mm DUCT
21
1
22
JUSP
1m OUTREACH STREET LIGHT
CYCLE PB ON POLE (27)
1
INDUCTANCE LOOP - STOPLINE
TO CALL PED 5
23
1
LOOP AND LOOP NUMBER
24
11
12
INDUCTANCE LOOP - ADVANCE
25
1
LOOP AND LOOP NUMBER
26
1
INDUCTANCE LOOP - CYCLE
NORTHBOUND OFF RAMP
27
1
MEMORIAL AVENUE
LOOP AND LOOP NUMBER
28
1
29
1
30
1
31
1
5
0
5
10
15
20
25
1:250 (A1)
DIMENSIONS ARE IN METRES
NZTA 62185 WAIRAKEI ROAD TO YALDHURST ROAD 4-LANING
HAREWOOD ROAD TO AVONHEAD PARK
CONSTRUCTION
TRAFFIC SIGNAL LAYOUT
MEMORIAL INTERSECTION WEST (SHT 2 OF 4)
C-11-002
10