This is an HTML version of an attachment to the Official Information request 'Fluoride Supply Chain Information'.
link to page 7 link to page 9 link to page 9
Published January 14, 2019 
 
 
Fact Sheet on Fluoridation Products and Fluoride 
 
Background 
 
NSF International (www.nsf.org) is an independent, global not-for-profit organization that facilitates 
standards development, and tests and certifies products for the food, water, health sciences and 
consumer goods industries to minimize adverse health effects and protect the environment. Founded in 
1944, NSF is committed to protecting human health and safety worldwide. NSF International is a Pan 
American Health Organization/World Health Organization (WHO) Collaborating Center on Food Safety, 
Water Quality and Indoor Environment. 
NSF/ANSI 60 
 
NSF/ANSI 60: Drinking Water Treatment Chemicals - Health Effects was developed to establish minimum 
requirements for the control of potential adverse human health effects from products added directly to 
water during its treatment, storage and distribution. The standard requires a full formulation disclosure 
of each chemical ingredient in a product to allow for a comprehensive evaluation of the products and 
their ingredients. The standard requires testing of the treatment chemical products, typically by dosing 
these in water at 10 times the maximum use level (MUL), so that trace levels of contaminants can be 
detected. A further evaluation of test results is required to determine if the concentrations of any 
detected contaminants have the potential to cause adverse human health effects. When health effects 
criteria have not been established for a given product or contaminant, the standard requires that health 
effects criteria be derived according to the requirements of Annex A prior to approval under this 
standard. For More Information on NSF/ANSI 60… 
 
Product Certification 
 
NSF’s testing and certification program for drinking water treatment products was developed in the late 
1980s to ensure that individual U.S. states and waterworks facilities have a mechanism to determine 
which products are most suitable for use.  The NSF certification program requires annual, unannounced 
inspections of production and distribution facilities to ensure that the products are properly formulated, 
packaged and transported with appropriate safe guards in place to protect against potential 
contamination.  NSF also requires annual testing and evaluation of each NSF certified product to confirm 
contaminants do not exceed drinking water health effects criteria. For More Information on Product 
Certification… 
 
Fluoride 
 
Fluoride Properties and Water Applications 
 
Water fluoridation is the practice of adjusting the fluoride content of drinking water. Fluoride is added 
to  water  for  the  public  health  benefit  of  greatly  reducing  the  incidence  of  tooth  decay  and  therefore 
improving the health of the community. For more information please visit the U.S. Centers for Disease 
Control and Prevention: www.cdc.gov/fluoridation/. 
  

 
 
 
NSF certifies three products in the fluoridation category: 
1.  Fluorosilicic acid (aka fluosilicic acid or hydrofluosilicic acid) 
2.  Sodium fluorosilicate (aka sodium silicofluoride) 
3.  Sodium fluoride 
 
All  three  products  readily  dissociate  in  water  to  release  fluoride  and  related  ions.  In  the  case  of  the 
fluorosilicates,  they  fully  dissociate  to  fluoride  and  silicate  ions  in  association with  either  hydrogen or 
sodium ions1. In the case of sodium fluoride, it fully dissociates to form fluoride and sodium ions. 
 
Treatment products that are used for fluoridation are specifically addressed in Section 7 of NSF/ANSI 60.  
The standard requires that the treatment products added to drinking water, as well as any impurities in 
the products, are supported by an evaluation of potential health effects resulting from exposure to the 
products or associated contaminants.  The following text explains the allowable levels established in the 
standard  for  1)  fluoride,  2)  silicate  and  3)  other  potential  contaminants  that  may  be  associated  with 
fluoridation chemicals. 
 
Fluoride Drinking Water Criteria 
 
NSF/ANSI 60 requires, when available, that the U.S. or Canadian regulatory values be used to determine 
the acceptable level for a chemical of interest.  The EPA MCL for fluoride ion in water is 4 mg/L and the 
Health  Canada  MAC  for  fluoride  is  1.5  mg/L  to  protect  against  skeletal  fluorosis.    However,  in  2003, 
representatives  from the EPA and Health Canada reviewed the  evaluation criteria in  NSF/ANSI  60 and 
recommended  that  the  TAC  and  SPAC  for  fluoride  ion  in  drinking  water  contributed  by  fluoridation 
products be lowered to 1.2 mg/L to match the upper bound of the U.S. Public Health Service/Centers for 
Disease  Control  recommended  fluoride  concentration  range  to  prevent  dental  fluorosis  (an  aesthetic 
effect).  The Drinking Water Additives Joint Committee for NSF/ANSI 60 supported this recommendation 
and set the acceptance criteria for fluoride ion equivalent to the maximum recommended fluoride ion 
dose.  For treatment chemicals other than fluoridation products, the allowable fluoride contribution is 
0.12 mg/L, or a tenth the TAC.   
 
In  2015,  the  U.S.  Department  of  Health  and  Human Services  recommended  that  the optimal  range  of 
water fluoridation of 0.7 to 1.2 ppm (mg/L) be updated to an optimal concentration of 0.7 ppm (mg/L) 
due to observations of increasing amounts of fluoride in food that is processed with fluoridated drinking 
water. Some U.S. states have elected to adopt this optimal concentration for fluoridation of community 
water supplies. Testing these chemicals at the higher use level of 1.2 ppm (as is currently done) provides 
a more conservative screening for contaminants in or associated with use of these products. 
 
More  recently,  the  U.S.  Centers  for  Disease  Control  and  Prevention  (CDC)  has  proposed  that  the 
recommended  operational  range  for  community water  supplies  be  narrowed  to 0.6  mg/L  to  1.0 mg/L 
fluoride  ion2.  The  CDC  advised  that  this  change  is  to  reflect  demonstrated  ability  of  water  utilities  to 
maintain  control of  fluoride  concentration  around  the  0.7  mg/L  optimum  concentration.  The  Drinking 
                                                 
1 Finney WF, Wilson E, Callender A, Morris MD, Beck LW. Reexamination of hexafluorosilicate hydrolysis by fluoride 
NMR and pH measurement. Environ Sci Technol 2006;40:8:2572) 
2 Centers for Disease Control and Prevention. Proposed Guidance Regarding Operational Control Range Around 
Optimal Fluoride Concentration in Community Water Systems that Adjust Fluoride
. Federal Register Vol. 83, No. 
135. 


 
 
Water Additives Joint Committee for NSF/ANSI 60 is reviewing whether it should lower the fluoride ion 
typical use level from 1.2 mg/L to 1.0 mg/L. If this request is approved by the Drinking Water Additives 
Joint Committee, it will be incorporated into NSF/ANSI 60 in 2019. 
 
Silicate Drinking Water Criteria 
 
Fluorosilicates do not  require  a toxicological assessment specifically for the fluorosilicate ion, because 
measurable levels of this ion do not exist in potable water at the fluoride concentrations and pH levels 
typical of public drinking water.3 There is currently no U.S. EPA-derived MCL or Health Canada MAC for 
silicate in drinking water.  The current sodium silicate typical use level (TUL) of 16 mg/L is listed in Table 
5.1 of NSF/ANSI 60, which was based on the value for sodium silicate published in the Water Chemicals 
Codex.4    A  fluorosilicate  product,  applied  at  its  maximum  use  level  (noted  below),  results  in  silicate 
drinking water levels that are substantially below the 16 mg/L TUL.  For example, a sodium fluorosilicate 
product dosed at a concentration into drinking water that would provide the maximum concentration of 
fluoride currently permitted by NSF/ANSI 60 (1.2 mg/L) would only contribute 0.8 mg/L of silicate – or 5 
percent of the TUL allowed by NSF/ANSI 60 for silicate.  
 
Fluoridation Product Use Levels 
 
Allowable use levels for fluoridation chemicals are limited by the NSF/ANSI 60 limits for fluoride ion.  Per 
the previous section, the silicate contribution is not a limiting factor.  The allowable maximum use levels 
(MUL) for NSF/ANSI 60 certified fluoridation products in 2018 are: 
 
1.    Fluorosilicic acid: 6 mg/L 
2.  Sodium fluorosilicate: 2 mg/L 
3.  Sodium fluoride: 2.3 mg/L 
 
Potential Contaminants in Fluoridation Chemicals
 
 
The product review conducted by NSF for a water treatment product considers all chemical ingredients 
in  the  product,  as  well  as  the  manufacturing  process,  processing  aids  and  other  factors  that  have  an 
impact  on  the  chemicals  attributable  to  the  products  present  in  the  finished  drinking  water.    The 
identified chemicals of interest are subsequently evaluated during testing of the product.  For example, 
fluosilicic  acid  is  produced  by  adding  sulfuric  acid  to  phosphate  ore.    This  is  typically  done  during  the 
production of phosphate additives.   The manufacturing process is documented by an NSF auditor at the 
initial  audit  of  the  manufacturing  site  and  during  each  subsequent  annual  unannounced  audit  of  the 
facility.  The manufacturing process, ingredients and potential contaminants are reviewed annually, and 
the  product  is  tested  for  any  potential  contaminants  of  interest.  A  minimum  test  battery  for  all 
fluoridation  products  includes  heavy  metals  of  toxicological  concern  and  radionuclides  because  they 
may be contained in phosphate ore. 
 
Many  drinking  water  treatment  additives,  including  fluoridation  products,  are  transported  in  bulk  via 
tanker  trucks  to  terminals  where  they  are  transferred  to  rail  cars,  shipped  to  distant  locations  or 
transferred into tanker trucks, and then delivered to the water treatment plants. These tanker trucks, 
                                                 
3 Finney WF, Wilson E, Callender A, Morris MD, Beck LW. Reexamination of hexafluorosilicate hydrolysis by fluoride 
NMR and pH measurement. Environ Sci Technol 2006;40:8:2572) 
4 National Academy of Sciences, Water Chemicals Codex, 1982 
 


 
 
transfer  terminals  and  rail  cars  are  potential  sources  of  contamination.  Therefore,  NSF  also  inspects, 
samples, tests and certifies products at rail transfer and storage depots.  It is always important to verify 
that the location of the product distributor (the company that delivers the product to the water utility) 
matches that shown in the official NSF listing for the product (available at www.nsf.org). 
  
NSF has compiled data on the levels of contaminants found in or through use of all fluoridation products 
that have applied for, or have been approved for, certification by NSF under NSF/ANSI 60. The results in 
Tables 1, 2, and 3 include those from the initial and annual monitoring tests for fluoridation products 
that NSF certified to NSF/ANSI 60 from 2012 to 2017 (Table 1), 2007 to 2011 (Table 2) and 2000 to 2006 
(Table 3). This summary includes 245 separate samples analyzed during the time period of 2000 to 2006, 
216 samples in the period of 2007 to 2011, and 328 samples in the period of 2012 to 2017. The 
concentrations reported represent contaminant levels expected when the products are dosed into 
water at the manufacturer’s maximum use level (MUL). For the time periods summarized below, the 
typical product certification and evaluation were based on a fluoride ion dose of 1.2 mg/L.  Lower 
product use levels would produce proportionately lower contaminant concentrations (e.g. a 0.6 mg/L 
fluoride dose would produce one half the contaminant concentrations listed in Table 1). 
 
The data reported in Tables 1, 2, and 3 demonstrate that very low concentrations of contaminants are 
associated with fluoridation chemicals. In fact, NSF was only able to detect the reported trace amounts 
by dosing the chemicals into reagent water at 10 times the manufacturer’s maximum use level (as 
required by NSF/ANSI 60) and then mathematically adjusting the laboratory results to expected field 
dose. If the products had been dosed into water at the manufacturer’s maximum use level, only one 
copper contaminant concentration would have been above the analytical method detection limits. This 
is demonstrated by comparing the results in columns 3 and 4 with the detection limits in column 5. The 
low concentrations of contaminants documented for this most current time period are explained, at 
least in part, by the ongoing effectiveness of NSF/ANSI 60 and the NSF certification program for drinking 
water treatment additives. The levels in Table 1 are comparable to those documented earlier for the 
2000-2011 time period, which is further attested to by a 2004 article in the Journal of the American 
Water Works Association entitled, “Trace Contaminants in Water Treatment Chemicals.”3 
 
Summary 
All the fluoridation products tested by NSF, when evaluated at their maximum use level in water, meet 
the health effects requirements of NSF/ANSI 60.  Arsenic was periodically detected in half of all samples.  
However,  the  mean  arsenic  concentration  is  1/50th  of  the  U.S.  EPA  MCL  and  none  of  the  samples 
exceeded 1/10th the U.S. EPA MCL.  The majority of fluoridation products certified by NSF do not contain 
detectable concentrations of lead, radionuclides or other heavy metals when dosed into water at their 
maximum use level.  In summary, fluoridation products certified by NSF do not contribute a significant 
contaminant burden to drinking water. 
 


 
 
Table 1. Fluoridation product chemical contaminant analysis from 2012-2017 (328 samples) 
 
Percentage 
Mean1 
Maximum 
Analytical 
NSF/ANSI 60 
U.S. EPA 
of Samples 
Contaminant 
Contaminant 
Method 
Single Product 
Maximum 
With 
Concentration 
Concentration 
Detection 
Allowable 
Contaminant 
Detectable 
in All Samples  
in Detectable 
Levels 
Concentration 
or Action 
Levels 
(ppb) 
Samples (ppb) 
(ppb) 
(ppb) 
Level (ppb) 
 
Antimony 
<1% 
0.022 
0.07 
0.5 
0.6 

Arsenic 
52% 
0.16 
0.9 


10 
Barium 
<1% 
0.045 
0.5 

200 
2000 
Beryllium 
0% 
ND 
ND 
0.5 
0.4 

Cadmium 
0% 
ND 
ND 
0.2 
0.5 

Chromium 
<1% 
0.044 
0.2 

10 
100 
Copper 
6% 
0.061 
2.8 

130 
1300 
Lead 
5% 
0.037 
0.3 
0.5 
1.53 
15 
Mercury 
<1% 
0.0088 
0.02 
0.2 
0.2 

Radionuclides 
0.12 pCi/L 
0.5 pCi/L 
3 pCi 
1.5 pCi/L 
15 pCi/L 
<1% 
– alpha 
Radionuclides 
0.16 pCi/L2 
0.6 pCi/L2 
4 pCi 
0.4 mrem/yr2 
4 mrem/yr2 
<1% 
– beta 
Selenium 
1% 
0.096 
1.1 


50 
Thallium 
<1% 
0.0088 
0.02 
0.2 
0.2 

1Mean values were calculated by setting the non-detectable (ND) values to half of the method detection level. 
2The corrected gross beta detection in radioactivity (pCi) per volume of water (L) is compared against the U.S. EPA 
limit of 4 mrems/yr for beta particle emitters in drinking water.  A mrem is a dose equivalent unit from ionizing 
radiation to an organ, organ system or the total body. The conversion factor from pCi/L to mrem is based on the 
strength of the beta radiation from a particular beta emitting isotope. The beta detections above were determined 
to be less than the 0.4mrem/yr limit of NSF/ANSI 60. 
3The NSF/ANSI 60 single product allowable concentration (SPAC) for lead was lowered from 1.5 µg/L to 0.5 µg/L in 
the published 2017 edition of NSF/ANSI 60.  However, this standard edition was published at the end of 2017 and 
all the lead results summarized in Table 1 were compared against the 1.5 µg/L SPAC. 
 


 
 
Table 2. Fluoridation product chemical contaminant analysis from 2007-2011 (216 samples) 
 
Percentage 
Mean1 
Maximum 
Analytical 
NSF/ANSI 60 
U.S. EPA 
of Samples 
Contaminant 
Contaminant 
Method 
Single Product 
Maximum 
With 
Concentration 
Concentration 
Detection 
Allowable 
Contaminant 
Detectable 
in All Samples  
in Detectable 
Levels 
Concentration 
or Action 
Levels 
(ppb) 
Samples (ppb) 
(ppb) 
(ppb) 
Level (ppb) 
 
Antimony 
0% 
ND 
ND 
0.5 
0.6 

Arsenic 
50% 
0.15 
0.6 


10 
Barium 
2% 
0.042 
0.6 

200 
2000 
Beryllium 
0% 
ND 
ND 
0.5 
0.4 

Cadmium 
0% 
ND 
ND 
0.2 
0.5 

Chromium 
<1% 
0.039 
0.3 

10 
100 
Copper 
<1% 
0.039 
0.091 

130 
1300 
Lead 
<1% 
0.037 
0.088 

1.5 
15 
Mercury 
0% 
ND 
0.04 
0.2 
0.2 

Radionuclides 
<1% 
0.18 pCi/L 
0.3 pCi/L 
3 pCi/L 
1.5 pCi/L 
15 pCi/L 
– alpha  
Radionuclides 
<1% 
0.19 pCi/L2 
0.5 pCi/L2 
4 pCi/L 
0.4 mrem/yr2 
4 mrem/yr2 
– beta  
Selenium 
0% 
ND 
ND 


50 
Thallium 
<1% 
0.0079 
0.01 
0.2 
0.2 

1Mean values were calculated by setting the non-detectable (ND) values to half of the method detection level. 
2The corrected gross beta detection in radioactivity (pCi) per volume of water (L) is compared against the U.S. EPA 
limit of 4 mrems/yr for beta particle emitters in drinking water.  A mrem is a dose equivalent unit from ionizing 
radiation to an organ, organ system, or the total body. The conversion factor from pCi/L to mrem is based on the 
strength of the beta radiation from a particular beta emitting isotope. The beta detections above were determined 
to be less than the 0.4mrem/yr limit of NSF/ANSI 60. 
 
 


 
 
 
Table 3. Fluoridation product chemical contaminant analysis from 2000-2006 (245 samples) 
 
Percentage 
Mean1 
Maximum 
Analytical 
NSF/ANSI 60 
U.S. EPA 
of Samples 
Contaminant 
Contaminant 
Method 
Single Product 
Maximum 
With 
Concentration 
Concentration 
Detection 
Allowable 
Contaminant 
Detectable 
in All Samples  
in Detectable 
Levels (ppb) 
Concentration 
or Action 
Levels 
(ppb) 
Samples (ppb) 
(ppb) 
Level (ppb) 
 
Antimony 
0% 
ND 
ND 
0.5 
0.6 

Arsenic 
43% 
0.12 
0.6 


10 
Barium 
<1% 
0.001 
0.3 

200 
2000 
Beryllium 
0% 
ND 
ND 
0.5 
0.4 

Cadmium 
1% 
0.001 
0.12 
0.2 
0.5 

Chromium 
<1% 
0.001 
0.2 

10 
100 
Copper 
3% 
0.02 
2.6 

130 
1300 
Lead 
2% 
0.005 
0.6 

1.5 
15 
Mercury 
<1% 
0.0002 
0.04 
0.2 
0.2 

Radionuclides 
0% 
ND 
ND 
3 pCi/L 
1.5 pCi/L 
15 pCi/L 
– alpha  
Radionuclides 
0% 
ND 
ND 
4 pCi/L2 
0.4mrem/yr2 
4 mrem/yr2 
– beta  
Selenium 
<1% 
0.016 
3.2 


50 
Thallium 
<1% 
0.0003 
0.06 
0.2 
0.2 

1Mean values were calculated by setting the non-detectable (ND) values to half of the method detection level. 
2The corrected gross beta detection in radioactivity (pCi) per volume of water (L) is compared against the U.S. EPA 
limit of 4 mrems/yr for beta particle emitters in drinking water.  A mrem is a dose equivalent unit from ionizing 
radiation to an organ, organ system, or the total body. The conversion factor from pCi/L to mrem is based on the 
strength of the beta radiation from a particular beta emitting isotope.  
 
 
 
 
Additional information on fluoridation of drinking water can be found on the following websites: 
 
American Dental Association (ADA) 
 
https://www.ada.org/en/public-programs/action-for-dental-health/prevention-and-education  
 
 
U.S. Centers for Disease Control and Prevention (CDC)  
http://www.cdc.gov/fluoridation 


 
 
More Information on NSF/ANSI 60  
 
The standard requires that the treatment products added to drinking water, as well as any impurities in 
the products, are supported by an evaluation of potential health effects resulting from exposure to the 
products and/or associated contaminants during the anticipated use(s) of the product.  It is a 
requirement of NSF/ANSI 60 (Annex A) that a determination be made as to whether a published and 
peer-reviewed quantitative risk assessment for the substance is available. If the substance is regulated 
by the U.S. EPA or Health Canada, these regulatory limits are to be used to derive the drinking water 
criteria for the regulated chemical of interest. If the identified published assessment is not the basis of a 
drinking water regulation, the assessment and its corresponding reference dose must be reviewed for its 
appropriateness in evaluating the human health risk of the substance.  If a published assessment is not 
identified or an identified assessment is deemed unacceptable, it is required that a comprehensive risk 
assessment be conducted from which drinking water criteria are derived.  The non-regulatory drinking 
water criteria derived from a risk assessment are known as total allowable concentrations (TAC), as 
stipulated in Annex A. 
 
Single Product Allowable Concentrations (SPAC) 
Guidance for derivation of drinking water criteria known as single product allowable concentrations 
(SPAC) is provided in Annex A of NSF/ANSI 60. The SPAC is defined as the maximum concentration of a 
contaminant in drinking water that a single product can contribute.  For contaminants regulated by the 
U.S. EPA or Health Canada, the SPAC is set to a default level that is not to exceed 10 percent of the 
regulatory level to address the possibility that multiple sources of the contaminant exist in the water 
supply. For contaminants that are not regulated, the SPAC is derived from the total allowable 
concentration (TAC), which is defined as the maximum concentration of a non-regulated contaminant 
permitted in public drinking water supply.  The default SPAC in these instances is one-tenth of the TAC 
to account for the possibility that more than one product in the water and/or its distribution system 
could contribute the contaminant of interest to drinking water.  Whether the chemical of interest is 
regulated or not, a lower or higher number of sources of the chemical in the drinking water supply can 
be specified if chemical-specific data are available to warrant deviating from the default. 
 
How the Standard Was Developed 
Development of NSF/ANSI 60 was initiated in 1985 at the request of U.S. EPA as part of a larger EPA/FDA 
MOU under the Safe Drinking Water Act, to establish modern testing, evaluation and acceptance criteria 
for product added directly to water during its treatment, storage and distribution.  The NSF 
International-led consortium, including the American Water Works Association (AWWA), the American 
Water Works Association Research Foundation (AWWARF), the Association of State Drinking Water 
Administrators (ASDWA) and the Conference of State Health and Environmental Managers (COSHEM), 
completed development in 1988.  
 
Who Maintains the Standard 
NSF/ANSI 60 is one of nearly 90 consensus-based standards to which NSF has contributed significantly. 
While NSF’s Standards department provides the support and structure for the development and 
publication of product standards, it is the Joint Committee on Drinking Water Additives which continues 
to review and maintain the standard annually.  This committee consists of representatives from the 
original stakeholder groups including the U.S. EPA as well as other regulatory, water utility and product 
manufacturer representatives. Every NSF standard is reviewed by NSF’s Council of Public Health 
Consultants (CPHC) whose role is to determine that the health-effects standards developed with support 


 
 
from NSF continue to aid in the protection of public health.  The American National Standards Institute 
(ANSI) has an oversight role in the standards process to ensure that the documents are developed and 
maintained according to their guidelines; ANSI makes all proposed revisions to ANSI standards available 
for public comment on its website at www.ansi.org 
 
More Information on Product Certification 
 
Product Review and Testing 
The product review conducted by NSF for a water treatment product considers all chemical ingredients 
in the product, as well as the manufacturing process, processing aids and other factors that have an 
impact on the chemicals attributable to the products present in the finished drinking water.  The 
identified chemicals of interest are subsequently evaluated during testing of the product.  The 
manufacturing process is documented by an NSF auditor at an initial audit of the manufacturing site and 
during each annual unannounced inspection of the facility.  The manufacturing process, ingredients, 
potential contaminants and label information are reviewed annually, and the product is tested for any 
potential contaminants of interest at NSF laboratories.  
 
NSF’s Mark and Public Product Listings 
All NSF certified products bear the NSF mark, maximum use level, lot number or date code, and 
production location on the product packaging or documentation shipped with the product.  
NSF maintains listings of certified products at www.nsf.org/certified-products-systems. These listings are 
updated daily and list the products at their allowable maximum use levels.  
 
History of the Product Certification Program  
The NSF testing and certification program for drinking water treatment products was developed in the 
1980s at the request of the U.S. EPA to provide an updated, science-based process to evaluate the use 
of drinking water treatment chemicals in public water supplies, based on NSF/ANSI 60.    This 
certification program was intended by U.S. EPA to eventually replace the EPA’s Advisory Program to 
States, which it did in 1990.  The states quickly adopted EPA’s recommendations to rely on certified 
products to help ensure that individual U.S. states and waterworks facilities have a mechanism to 
identify and select treatment chemicals for use in public water supplies.   
 
Who Uses the Standard 
According to the latest Association of State Drinking Water Administrators (ASDWA) Survey on State 
Adoption of NSF/ANSI Standards 60 and 61, 49 U.S. states require that chemicals used in treating 
potable water meet NSF/ANSI 60 requirements.  In Canada, nine provinces/territories require drinking 
water treatment chemicals to comply with the requirements of NSF/ANSI 60. Certification to NSF/ANSI 
60 is also recognized in several other countries, including Brazil, Israel, UAE, Saudi Arabia, Singapore and 
South Africa. Manufacturers can choose to apply to NSF International or another ANSI-accredited 
certifying body for certification to the standard. If you have questions on your state's requirements, or 
how the NSF/ANSI 60 certified products are authorized in your state, contact your state's Drinking Water 
Administrator or download a state survey summary at 
http://www.nsf.org/newsroom_pdf/water_asdwa_survey.pdf. 


 
 
Abbreviations Used in This Fact Sheet 
 
ANSI – American National Standards Institute 
 
AWWA – American Water Works Association 
 
AWWARF – American Water Works Association Research Foundation 
 
ASDWA – Association of State Drinking Water Administrators 
 
CDC – Centers for Disease Control and Prevention 
 
COSHEM – Conference of State Health and Environmental Managers 
 
EPA – U.S. Environmental Protection Agency 
 
MAC – maximum allowable level 
 
MCL – maximum contaminant level 
 
mrem/yr – millirems per year – measurement of radiation exposure dose 
 
MUL – maximum use level 
 
NSF – NSF International (formerly the National Sanitation Foundation) 
 
ppb – parts per billion  
 
pCi/L – pico curies per liter – concentration of radioactivity 
 
SPAC – single product allowable concentration 
 
TAC – total allowable concentration 
 
10