TABLE OF WATER MONITORING PROGRAMMES 
FOLLOWING 1080 AERIAL BAITING OPERATIONS 
 
 
 
The Drinking-Water Standards for New Zealand, issued in 2005 (revised 2018) by the Ministry of Health, specify a Provisional Maximum Acceptable 
Value (PMAV) for 1080 in water of 3.5 ppb. The PMAV value is one that, on the basis of present knowledge, is not considered to cause any significant 
risk to the health of the consumer over a lifetime of consumption of the water. However, the Ministry of Health also recommends that water taken 
from catchments sown with 1080 baits should not be used for human supply until tests show that the concentration of 1080 is below 2 ppb. The 
figure of 2 ppb is an approximation of 50% of the PMAV value, and is applied to testing water for 1080 as a precautionary/conservative measure. 
 
 
 
 
 
 
 
Operation by Region 
Date 
Positive 
Conc. 1080 
Remarks 
(conc. 1080 in %) 
samples 
detected, ppb 
(noted where provided by Client) 
 
 
 
 
 
Otago (0.02%) 
7/92 
12 
10 < 0.3 
 
1 = 0.3 
1 = 0.6 
 
 
 
 
 
Taranaki (0.15%) 
5-8/93 
18 
18 < 0.3 
Contaminated containers 
 
 
 
 
 
Auckland (0.08 and 0.15%) 
6/94 

1 = 0.7 
Reticulated = 7 
1 = 0.5 
1 = 0.4 
2 = 0.3 
1 = 0.2 
2 = 0.1 
 
 
 
 
 
Marlborough (0.15%) 
 
 
1 = 0.1 
Sample with high result taken from bay at 6.00pm on 11/8/94 
 
8/94 

1 = 0.5 
 
 
 
 
1 = 3.4 
 
 
 
1 = 0.4 
Tasman (0.15%) 
8/94 

1 = 0.6 
Page 1 of 4 

 
 
 
 
 
Operation by Region 
Date 
Positive 
Conc. 1080 
Remarks 
(conc. 1080 in %) 
samples 
detected, ppb 
(noted where provided by Client) 
 
 
 
 
 
Manawatu-Wanganui (0.08%) 
10-
 
 
Positive from site with bait visible in stream 
11/94 

0.2 
 
 
 
 
 
Waikato (0.15%) 
8-12/94 

0.8 
Positive sample where baits close to stream 
 
 
 
 
 
Canterbury (0.08%) 
5-6/95 

0.2 
 
 
 
 
 
 
Hawke's Bay (0.08%) 
~9/95 

0.3 
 
 
 
 
 
 
Gisborne (0.15%) 
5/96 

0.2 
Bait observed near stream 
 
 
 
 
 
Manawatu-Wanganui (0.15%) 
10/96 

0.1 
 
 
 
 
 
Manawatu-Wanganui (0.08%) 
9/96 

3.5 
Contaminated sample at horseshoe bend 48 hours after 
operation 
 
 
 
 
 
Waikato 
9/97 

2.4 
Taken from spillway of hydro lake.  Think this was container 
 
 
 
contamination from overalls 
 
 
 
 
 
Bay of Plenty (0.15%) 
10-

0.5 
Sample from head-water junction, low flow, on day of drop, 
 
11/97 
baits observed in water 
 
 
 
 
 
Taranaki 
5-7/98 

1=9.0 
High result from sample taken on day of operation at weir 
1=0.6 
downstream from carrot baiting.  Operator wearing 
contaminated overalls, took sample in the dark.   
 
 
 
 
 
Bay of Plenty (0.15%) 
8/99 

1 = 4.0 
Positive samples taken at Site 2; same day and at 24 hours.  
1 = 1.0 
Resample after 6 days was negative.   
 
 
 
 
 
Marlborough (0.15%) 
9/99 

0.2 
 
 
 
 
 
 
Tasman 
7/00 

0.5 
 
 
 
Canterbury 
5/01 

0.3 
 
 
 
No reason for +ve. 
Page 2 of 4 

 
 
 
 
 
Operation by Region 
Date 
Positive 
Conc. 1080 
Remarks 
(conc. 1080 in %) 
samples 
detected, ppb 
(noted where provided by Client) 
Tasman (0.15%) 
6/01 

0.2 
 
Otago 
7/02 

0.8 
 
The first +ve on the day after the drop, and the second on the 
Canterbury 
8/02 

1=1.0 
1=0.8 
day of the drop.  Both sites within the treatment area.  Bait 
seen on the access road. 
Hawkes Bay 
9/02 

0.6 
 
Canterbury (0.15%) 
7/04 

0.2 
Sample taken on the day of the operation, from a small 
stream. 
Waikato (0.15%) 
5/05 

0.2 
Positive sample taken from river on 25/5/05: 2300hrs. 
Southland 
7/05 

0.2 
 
Manawatu-Wanganui 
8/05 

1 = 0.1 
1 = 0.4 
 
West Coast 
1/06 

0.1 
 
Hawkes Bay 
5/06 

1.3 
 
Waikato 
9/06 

0.1 
 
Bay of Plenty 
9/06 

1 = 0.1 
1 = 0.5 
 
Southland 
10/06 

3 = 0.2 
1= 0.4 
 
West Coast 
1/07 

0.2 
Not a drinking water supply 
West Coast 
7/07 

0.2 
May have been a domestic water supply. 
Southland 
9/07 

1=0.5 
1= 2.3 
Samples from streams containing 1080 baits. 
West Coast 
8/08 

2=0.2 
Stock water supplies affected 
Manawatu-Wanganui 
12/08 

0.1 
Not a domestic supply 
Page 3 of 4 

 
 
 
 
 
Operation by Region 
Date 
Positive 
Conc. 1080 
Remarks 
(conc. 1080 in %) 
samples 
detected, ppb 
(noted where provided by Client) 
West Coast 
6/09 

0.2 
Water supply for a picnic area, closed down during operation 
West Coast 
6/09 

0.1 
Water tank for domestic and stock water supplied by a stream 
1=1.6 
West Coast 
8/09 

1=0.3 
Contamination of the sample bottles by the control operator 
1=0.5 
West Coast 
8/09 

0.1 
Not a domestic supply 
Canterbury 
7/09 

0.3 
No domestic supplies affected 
Waikato 
10/11 

1=0.6 
1=0.3 
Not domestic and possible bait in stream as overflown 
Waikato 
6/12 

0.2 
water supply 
Southland 
8/14 

1=0.1 
1=0.2 
Not a water supply 
Southland 
8/14 

0.2 
Not a water supply 
Waikato 
11/15 

0.1 
 
Taranaki 
12/16 

0.2 
 
West Coast 
12/16 

1=0.2 
1=0.3 
 
Taranaki 
12/16 

0.2 
 
Northland 
10/18 

0.1 
 
Manawatu-Wanganui 
11/18 

0.2 
 
 
Page 4 of 4 