This is an HTML version of an attachment to the Official Information request 'Crash data - Memorial Road/State Highway 1 intersection'.




NOTES:
INSTALL 5 x CAT5e OR CAT6, TO STREET
Pole Schedule
1.
THIS DRAWING IS TO BE READ IN CONJUNCTION WITH
LIGHTING COLUMN. CABLE TO BE LEFT IN
THE COMPLETE PROJECT DOCUMENTATION SET,
pole
type
equipment
THE BASE OF COLUMN, WITH LENGTH TO
INCLUDING THE SPECIFICATIONS.
REACH 3M PAST TOP OF COLUMN
1
1
2.
ALL TRAFFIC SIGNAL EQUIPMENT AND INSTALLATION
2
JUSP
STREET LIGHT + CCTV
SHALL COMPLY WITH THE NATIONAL TRAFFIC SIGNAL
3
5
5m MAST ARM, NO LIGHTING
SPECIFICATION AND CTOC SIGNALS SPECIFICATION
(REGIONAL SPECIAL CONDITIONS).
4
JUSP
1m OUTREACH STREET LIGHT
5
1
3.
CONTROLLER AND POLE POSITIONS ARE INDICATIVE
ONLY. FINAL LOCATIONS TO BE DETERMINED ON SITE BY
6
1
THE ENGINEER.
7
11
4.
ALL DUCTING UNDER  ROAD CARRIAGEWAYS TO BE 3 BY
8
1
100mm UPVC ORANGE ELECTRICAL CONDUIT. FEEDER
9
1
DUCTS WILL BE 50mm UPVC ORANGE ELECTRICAL
CONDUIT.
10
1
5.
SIGNAL DUCTING CHAMBER LOCATIONS ARE INDICATIVE
11
1
ONLY AND SHOULD BE CONFIRMED ON SITE. CHAMBERS
12
1
FUTURE COUNTING LOOP.
TO BE LOCATED OUT OF MAIN PEDESTRIAN PATHS AND
AWAY FROM UNDERGROUND SERVICES.
13
1
14
JUSP
1m OUTREACH STREET LIGHT
6.
ALL LANTERNS TO USE LED LAMPS
15
1
7.
LOOPS 1 AND 14 ARE CYCLE LOOPS
16
1
8.
POLES 5 AND 22 ARE STUB POLES HOUSING CYCLE PUSH
17
JUSP
1m OUTREACH STREET LIGHT + CCTV
50mm DIA DUCT TO FUTURE ADVANCE LOOP
BUTTONS. POLES 4,12,21 AND 25 ARE STANDARD POLES
35M FROM LIMIT LINE.
18
5
5m MAST ARM, NO LIGHTING
THAT ALSO HOUSE CYCLE PUSH BUTTONS.
19
1
9.
CYCLE PUSH BUTTONS  BE POSITIONED SO THAT THEY
20
1
ARE ACCESSIBLE TO CYCLISTS.
21
1
10. REFER TO DRAWINGS C-11-003 & 004 FOR PHASING,
22
JUSP
1m OUTREACH STREET LIGHT
DUCTING AND CABLE REQUIREMENTS
23
1
11. CONTRACTOR TO CONFIRM CABLE RUNS AND CABLE
24
11
CAPACITY REQUIREMENTS.
25
1
LEGEND:
CYCLE PB ON POLE (6)
6
26
1
TO CALL PED 7
CB 7(25)
CONTROLLER
27
1
SIGNAL DUCT ACCESS CHAMBER
28
1
9
FUTURE
KERBSIDE JUNCTION BOX (K.J.B.)
PB 4(29)
29
1
ADVANCE
5
PB 4(29)
LOOPS
30
1
POST AND POST NUMBER
CB 7(25)
4
31
1
8
POST WITH OVERHEAD STREETLIGHT (JUSP)
7
POST WITH OVERHEAD MAST ARM
PB 7(25)
200mm ASPECTS - OPEN VISOR
300mm ASPECTS - OPEN VISOR
PB 7(25)
ASPECTS WITH CLOSED VISOR
9
3 ASPECT DISPLAY
3 ASPECT DISPLAY WITH SINGLE GREEN
ARROW DISPLAY
19
3 ASPECT DISPLAY WITH THREE ARROW
DISPLAY
10
3 ASPECT DISPLAY WITH
SUPPLEMENTARY ARROW DISPLAY
PB 8(25)
3 ASPECT DISPLAY WITH SUPPLEMENTARY
TWO ARROW DISPLAY (R, Y AND G INDICATE
COLOUR OF ARROW DISPLAY)
3 ASPECT DISPLAY WITH SUPPLEMENTARY
THREE ARROW DISPLAY
PB 6(27)
PEDESTRIAN ASPECTS WITH PED PB AND
PB 8(25)
INPUT NUMBER
PEDESTRIAN CALL BOX 
17
P20
PEDESTRIAN CALL PAD AND INPUT NUMBER
11
PB 1(32)
PB 1(32)
32mm DUCTING
13
9
100mm DUCT
12
SH1 RUSSLEY ROAD
PB 8(25)
1
INDUCTANCE LOOP - STOPLINE
LOOP AND LOOP NUMBER
PB 8(25)
12
INDUCTANCE LOOP - ADVANCE
CB 1(32)
LOOP AND LOOP NUMBER
CYCLE PB ON POLE (14)
16
TO CALL PED 1
INDUCTANCE LOOP - CYCLE
14
LOOP AND LOOP NUMBER
FUTURE ADVANCE LOOP LOCATED 35M
FROM LIMIT LINE.
15
5
0
5
10
15
20
25
1:250 (A1)
DIMENSIONS ARE IN METRES
NZTA 62185 WAIRAKEI ROAD TO YALDHURST ROAD 4-LANING
HAREWOOD ROAD TO AVONHEAD PARK
CONSTRUCTION
TRAFFIC SIGNAL LAYOUT
MEMORIAL INTERSECTION EAST (SHT 1 OF 3)
C-11-001
9