Section A – Advice Notes 
 

Planning Advice Notes  
1.  Accessible  car  parking  spaces  shall  have  clear  ground  marking  in  accordance  with  the 
international symbol of access.  
2.  If  during  the  course  of  undertaking  the  site  works  there  is  a  discovery  made  of  any 
archaeological  find,  or  suspected  find,  the  work  on  that  portion  of  the  site  should  cease 
immediately and Heritage NZ and a representative of the relevant local Iwi contacted. It is 
unlawful  to  modify,  damage  or  destroy  an  archaeological  site  without  prior  authority  from 
1982
the  trust  under  the  Historic  Places  Act  1993.  Please  contact  Heritage  New  Zealand  to 
obtain the Accidental Discovery Protocol Guidelines. A point of contact is Bill Edwards via 
09 407 0470 or 09 407 0471 or [email address]  
3.   It  is  recommended  that  you  contact  Heritage  New  Zealand  to  discuss  your  proposal 
Act 
because Heritage New Zealand may require an archaeologist undertake an archaeological 
survey before works commence. 
4.  You must comply with the conditions of Resource Consent 2190517 Granted 18/04/19. 
5.  Before  issue  of  Code  Compliance  Certificate,  please  ensure  that  a  Vehicle  Crossing 
application  has  been  applied  for  and  granted  (application  form).  Vehicle  crossing  to  be 
constructed in accordance with Council’s Engineering Standards for Vehicle Crossings and 
all Bylaws of the Council in  force at  the time of such construction.   Any queries regarding 
this please on the Monitoring Team on 0800 920029. 
6.  Whilst the building consent  has now been issued,  we note that  some aspects  of the work 
Information 
involving Council-owned land will not be able to proceed until an encroachment license has 
been issued by the Council in its role as landowner. Please apply for a License to Occupy a 
Portion of Road in relation to the proposed Retaining Walls being constructed within Legal 
Road.  
7.  Assessment of your consent has highlighted the need for an Earthworks Permit under the 
Control of Earthworks Bylaw. Please note that this Earthworks Permit must be granted prior 
Official 
to any Earthworks commencing. If you require any assistance in this matter, please contact 
the Duty Planner on 0800 920 029 or [email address]  
 
the 
Documentation  
Please  read  all  documentation  associated  with  this  building  consent  in  detail,  documentation 
includes:  
  the building consent, which lists building consent conditions and any attachments, if applicable  
  a schedule of the inspection requirements for this project; and  
under 
  advice  on  any  documentation  that  maybe  required  for  example,  producer  statements  and 
certificates 
 
Booking inspections 
Please make sure that you call for the inspections identified in section B of this documentation. It 
is advisable that you plan your inspections well ahead of time and book these inspections with as 
much  notice  as  possible.  If  insufficient  notice  is  given,  Council  may  not  be  able  to  schedule  the 
inspection at your preferred time and this may cause construction delays.  
Released 
 
Consent documents on site  
Please  ensure  that  a  complete  set  of  the  approved  building  consent  documents  is  on  site  at  all 
times.   Plans must be printed to the original scale submitted for building consent and be collated 
into a set.    
 
 


 
 
Property ID: 3354000 
 
Changes during construction 
If you wish to make changes during construction, you will either have to apply for an amendment 
or a minor variation. 
 
An amendment is something that materially affects compliance (e.g. structural changes) whereas 
a minor variation is a small change (e.g. changing the brand of insulation). 
 
Amendments  must  be  applied  for  in  the  same  manner  as  if  it  were  a  building  consent.    Minor 
variations can be approved on site. 
1982
 
Water meter; waste water and storm water connections 
If  you  require  a  water  meter  or  connection  to  Council  services,  you  must  seek  approval  from 
Act 
Councils  Infrastructure  Department.  Application  forms  are  available  on  our  website  at: 
https://www.fndc.govt.nz/services/forms-and-pamphlets-index/water-wastewater-and-refuse  
 
Information 
Official 
the 
under 
Released 


 
 
Property ID: 3354000 
Section B - Schedule of Inspections  
The  following  inspections  have  been  identified  as  required  for  this  building 
project: 
 
209A 

Strip Footing Foundation 
To  check  soil  conditions  and  the  size  and  depth  of  footings  prior  to  the 
placement of concrete.  All reinforcing steel must be in place and be tied and 
supported on chairs. Reinforcing steel appropriate grade and size.  
1982
Note: If you are unable  to locate survey pegs a Registered Land Surveyor’s 
certificate will be required and must be provided at time of inspection. 
 
Act 
209E 
Pole Retaining Wall Foundation 
To  check;  location  to  boundary,  size  and  depth  of  holes,  size  and  treatment 
level of poles, mPa of concrete to be used. 
 
212 
Under Slab Plumbing 
To check all under slab drainage and plumbing; all pipes to be under test and 
exposed for inspection. As-built plan and Plumber to be on site for inspection. 
 
Information 
213B 
Concrete Slab on-Grade 
To  check  that  hard  fill  has  been  compacted;  DPM  placed;  reinforcement  is 
tied  and  supported  in  chairs;  and  starter  bars  fitted.  A  string-line  must  be  in 
place to check slab thickness. 
Note: A PS4 is required where hard fill exceeds 600mm. 
If  you  are  unable  to  locate  survey  pegs  a  Registered  Land  Surveyor’s 
certificate will be required and must be provided at time of inspection. 
Official 
 
222A 
Wall and Roof Framing 
the 
To  check;  hold  down  straps,  bolts,  wall  and  roof  framing  members;  truss 
fixings,  wall  and  roof  bracing  tie  downs;  wall  framing;  beams  and  lintels; 
plywood substrates for membranes including falls and outlets. 
Note: This inspection is carried out prior to building wrap being fitted. 
 
under 
223 
Cavity Wrap 
To  check  the  cavity  has  been  formed;  cavity  battens;  cavity  closers  and 
flashings are all in place; windows to be fitted. 
 
226A 
Cladding 
To  check  the  installation  of  the  cladding  system;  junctions  between  different 
claddings,  flashings,  etc.,  to  ensure  that  the  exterior  of  the  building  is 
Released 
weathertight. 
 
 
 
 
 


 
 
Property ID: 3354000 
 
229A 
Preline Building 
To  check  the  building  is  weathertight,  proprietary  connections  for  bracing 
elements installed and moisture content below 18%, prior to fixing any internal 
linings and to check the installation of all wall, ceiling and mid-floor insulation 
(thermal and acoustic) prior to installing interior linings. 
Note:  Cladding  must  be  completed;  windows  installed  and  building 
completely weathertight. All services (electrical and plumbing) complete. 
 
1982
229B 
Preline Plumbing 
To check pipe work is under test (water supply and soil wastes); pressure test 
to be on at time of inspection. 
Act 
Note:  This inspection may be included with the Preline Building inspection. 
 
229C 
Insulation 
To check that all insulation has been friction fitted and is the correct R-value. 
 
237B 
Post Line (fire ratings) 
To  check  fire  rated  linings;  materials,  collars,  wraps  and  other  passive  fire 
protection  measures  including  suspended  ceilings  (if  applicable)  prior  to  any 
stopping. 
Information 
 
241A 
Drainage (conventional) 
To check that  all stormwater and sewer drains have been laid to the correct 
fall and are under test prior to backfilling trenches. 
Note: An as-built plan is required for all work at time of inspection. 
 
Official 
241C 
Stormwater Detention or Retention Tank 
To check the location and installation of any stormwater detention or retention 
the 
tanks. 
 
241D 
Effluent Disposal System, Septic Tank, Effluent Field 
To  check  the  correct  system  installed,  location,  filters,  dripper  lines,  surface 
water interception drains in place and field correct size for design. 
under 
 
306B 
Final Inspection - Commercial 
To  check  all  construction  associated  with  the  building  consent  has  been 
completed;  this  includes  painting  and  decorating;  floor  coverings;  fixtures; 
fittings;  electrical  work;  heating  appliances;  etc.  Ground  levels  established; 
driveways  and  car  parking  areas  formed  and  landscaping  completed.  All 
signage  (accessibility  and  egress)  in  place.  All  specified  systems  installed, 
tested and commissioned. 
Released 
Note: Electricity must be connected at time of inspection. 
 
 
 


 
 
Property ID: 3354000 
Section C – Documentation required 
The  following  producer  statements,  testing  certificates  and  warrantees  are 
required to confirm compliance during construction: 
 
Energy Works Certificate - Electrical 
The  electrician  is  required  to  submit  an  energy  works  certificate  certifying  that  all  electrical 
installations  meet  the requirements  of  Clause  G9  (Electricity)  of  the  New  Zealand Building  Code 
and the Electrical Regulations. 
1982
 
Fire Alarm System Certification 
The installer and an accredited inspection body are required to provide a Certificate of Completion 
Act 
for  Fire  Alarm  System  confirming  that  it  has  been  installed,  tested  and  commissioned  in 
accordance with the nominated performance standard.  
The  installer  must  also  provide  an  as-built  plan  showing  the  location  of  each  of  the  specified 
systems that they have installed. 
 
Other Specified Systems – Installation, Testing and Commissioning Certificates 
The  installer  must  provide  a  certificate  confirming  that  any  other  specified  systems  have  been 
installed,  tested  and  commissioned  in  accordance  with  the  nominated  performance  standard.  
Information 
Certificates are required for each of the following systems: 
  Emergency lighting 
  Emergency power supply 
  Interfaced/mechanical ventilation systems 
The  installer  must  also  provide  an  as-built  plan  showing  the  location  of  each  of  the  specified 
Official 
systems that they have installed. 
Wastewater (PS4) 
the 
Producer  statement  construction  review  (PS4)  is  to  be  submitted  by  the  engineer  for  the 
observation  and  construction  of  the  on-site  wastewater  treatment  and  disposal  system. 
Confirmation  is  also  required  that  the  work  complies  with  the  design  approved  by  this  building 
consent. 
under 
 
Water Tank 
Install water storage tank with minimum capacity 45,000 litres for fire-fighting purposes complete 
with an outlet compatible with Fire and Emergency NZ requirements. 
 
PS4 – Other 
Construction monitoring and PS4 from Wilton Joubert Ltd for: Site cut, fill compaction, footings 
Released 
pre-pour, beam connections/portal frame and retaining wall holes and poles. 
 
 